iaq_sensor_wired/tests/measure_multiple_devices.py
2021-10-20 20:38:37 +02:00

43 lines
1.9 KiB
Python
Executable File

#!/usr/bin/env python3
from time import sleep, time
from sys import exit
import minimalmodbus
import serial
slave_address_list = [ 252, 253 ]
# read
while True:
for slave_address in slave_address_list:
# initialize modbus
instrument = minimalmodbus.Instrument('/dev/rs485', slave_address, close_port_after_each_call=True) # port name, slave address (in decimal)
instrument.serial.baudrate = 115200
instrument.serial.bytesize = 8
instrument.serial.parity = serial.PARITY_EVEN
instrument.serial.stopbits = 1
instrument.serial.timeout = 0.05 # seconds
instrument.mode = minimalmodbus.MODE_RTU # rtu or ascii mode
instrument.clear_buffers_before_each_transaction = True
try:
CO2_addr = 9
CO2 = instrument.read_register(CO2_addr, 1, functioncode=4) * 10
T_SHT4x_addr = 10
T_SHT4x = instrument.read_register(T_SHT4x_addr, 1, functioncode=4)
RH_SHT4x_addr = 11
RH_SHT4x = instrument.read_register(RH_SHT4x_addr, 1, functioncode=4) * 10
T_SCD4x_addr = 12
T_SCD4x = instrument.read_register(T_SCD4x_addr, 1, functioncode=4)
RH_SCD4x_addr = 13
RH_SCD4x = instrument.read_register(RH_SCD4x_addr, 1, functioncode=4) * 10
T_SHT4x_signed_addr = 14
T_SHT4x_signed = instrument.read_register(T_SHT4x_signed_addr, 1, functioncode=4, signed=True)
T_SCD4x_signed_addr = 15
T_SCD4x_signed = instrument.read_register(T_SCD4x_signed_addr, 1, functioncode=4, signed=True)
with open(f'measurement_device_{slave_address}.csv', 'a+') as f:
f.write(f'{time():.1f} {CO2} {T_SHT4x} {RH_SHT4x} {T_SCD4x} {RH_SCD4x} {T_SHT4x_signed} {T_SCD4x_signed}\n')
except minimalmodbus.NoResponseError:
print(f'Read error for device {slave_address} at {time()}')
continue
sleep(10)