Wrote Features, Descriptions, Applications sections to datasheet

This commit is contained in:
Jan Mrna 2022-05-29 11:05:00 +02:00
parent 48c49356ca
commit b60498f1ff

View File

@ -11,10 +11,15 @@
% ONLY FOR TEMPLATE
\usepackage{blindtext}
%
% Sensor name definition
%
\newcommand{\sensor}{SM-IAQSW-01}
\pagestyle{fancy}
\fancyhf{}
\fancyhead[LE,LO]{\includegraphics[scale=0.075]{./fig/VelesLabsLogo.png}}
\fancyhead[RE,RO]{PRODUCT NAME\\DATASHEET v. 1.0}
\fancyhead[RE,RO]{\sensor{}\\DATASHEET v. 1.0}
\fancyfoot[LE,LO]{\leftmark}
\fancyfoot[RE,RO]{\thepage}
@ -25,30 +30,35 @@
\begin{document}
%TODO: TITLEPAGE
\begin{multicols*}{2}
\includegraphics[width=0.45\textwidth]{./fig/iaq_wired_sensor.png}
\section*{Features}
\begin{itemize}
\setlength\itemsep{0cm}
\item 260 to 1260 hPa absolute pressure range
\item Current consumption down to 3 A
\item High overpressure capability: 20x full-scale
\item Embedded temperature compensation
\item 24-bit pressure data output
\item 16-bit temperature data output
\item ODR from 1 Hz to 75 Hz
\item SPI and I²C interfaces
\item Embedded FIFO
\item Interrupt functions: Data Ready, FIFO flags, pressure thresholds
\item Supply voltage: 1.7 to 3.6 V
\item High shock survivability: 22,000 g
\item Small and thin package
\item ECOPACK lead-free compliant
\item Measures all important indoor air quality values: $\mathrm{CO_2}$, T, RH, VOC
\item Communicates via MODBUS RTU (RS-485)
\item Wide input voltage range 5 - 30V
\item Indicates $\mathrm{CO_2}$ (carbon dioxide) level using LED for quick air quality assesment
\item Easy to setup using Raspberry Pi and open-source Veles Sensors python library
\item Carbon dioxide measurement range 0 - 40000 ppm
\item Temperature range -40 - 125 °C
\item Relative humidity range 0 - 100 \%
\item VOC (volatile organic compounds) index range 1 - 500 VOC index points
\end{itemize}
\section*{Description}
\blindtext
\blindtext
\sensor{} is a wired indoor air quality sensor measuring temperature, relative humidity, carbon dioxide and volatile organic compounds. Communication over RS-485 using MODBUS RTU protocol makes it easy to interface with the sensor using PLC or any PC with RS-485 to USB converter. Open-source Python libraries are available to ease sensor configuration and readout using PC and embedded computers (e.g. Raspberry Pi).
On-board RGB LED enables user to quickly assess air quality with single glance. Two quality-to-color schemes are available: continuous color change and tri-state (semaphore) mode.
Wide input voltage range makes it possible to integrate sensor to many different systems, ranging from house-wide 12V bus to 5V USB connected to local computer.
Extended version of this sensor \sensor{}-PM adds particulate matter (dust) measurement option.
\section*{Application}
\begin{itemize}
\setlength\itemsep{0cm}
\item IAQ measurement for home and office spaces
\item Ventilation control (manual or automated)
\end{itemize}