Added software reset
This commit is contained in:
parent
771fd24f93
commit
5feb12310c
@ -96,6 +96,7 @@ int8_t uart_enable_interrupts(void);
|
|||||||
#endif
|
#endif
|
||||||
/* USER CODE BEGIN Private defines */
|
/* USER CODE BEGIN Private defines */
|
||||||
#define MEASUREMENT_PERIOD_MS 600000
|
#define MEASUREMENT_PERIOD_MS 600000
|
||||||
|
#define RESET_MAGIC_NUMBER 0xABCD
|
||||||
|
|
||||||
extern uint16_t usart2_rx_message_index;
|
extern uint16_t usart2_rx_message_index;
|
||||||
extern uint16_t usart2_rx_message_len;
|
extern uint16_t usart2_rx_message_len;
|
||||||
|
@ -89,7 +89,8 @@ enum
|
|||||||
REGISTER_NUM_CO2_ALERT_LIMIT2 = 40005,
|
REGISTER_NUM_CO2_ALERT_LIMIT2 = 40005,
|
||||||
REGISTER_NUM_SCD4x_T_OFFSET = 40006,
|
REGISTER_NUM_SCD4x_T_OFFSET = 40006,
|
||||||
REGISTER_NUM_MODBUS_ADDR = 40007,
|
REGISTER_NUM_MODBUS_ADDR = 40007,
|
||||||
REGISTER_NUM_BAUDRATE = 40008
|
REGISTER_NUM_BAUDRATE = 40008,
|
||||||
|
REGISTER_NUM_RESET_DEVICE = 40100
|
||||||
} config_registers_numbers;
|
} config_registers_numbers;
|
||||||
|
|
||||||
enum
|
enum
|
||||||
@ -931,6 +932,14 @@ int8_t modbus_slave_callback(modbus_transaction_t *transaction)
|
|||||||
sensor_config.baudrate_index = (uint16_t) (transaction->holding_registers[i]);
|
sensor_config.baudrate_index = (uint16_t) (transaction->holding_registers[i]);
|
||||||
baudrate_changed = 1;
|
baudrate_changed = 1;
|
||||||
break;
|
break;
|
||||||
|
case REGISTER_NUM_RESET_DEVICE:
|
||||||
|
if (transaction->holding_registers[i] == 0xABCD) {
|
||||||
|
/* software reset */
|
||||||
|
NVIC_SystemReset();
|
||||||
|
} else {
|
||||||
|
return MODBUS_ERROR_OUT_OF_BOUNDS;
|
||||||
|
}
|
||||||
|
break;
|
||||||
default:
|
default:
|
||||||
return MODBUS_ERROR_FUNCTION_NOT_IMPLEMENTED;
|
return MODBUS_ERROR_FUNCTION_NOT_IMPLEMENTED;
|
||||||
}
|
}
|
||||||
|
@ -8,7 +8,7 @@ f'''{argv[0]} ADDR [BAUDRATE] [{{read [REGISTER ...] | write VALUE REGISTER}}]
|
|||||||
where:
|
where:
|
||||||
- ADDR is Modbus address (use 0 for broadcast; note that only write can be broadcast)
|
- ADDR is Modbus address (use 0 for broadcast; note that only write can be broadcast)
|
||||||
- BAUDRATE is (optional) baud rate; default value is 19200
|
- BAUDRATE is (optional) baud rate; default value is 19200
|
||||||
- action can be "read", "write" or can be omitted (defaults to "read all")
|
- action can be "read", "write", "reset" or it can be omitted completely (defaults to "read all")
|
||||||
- REGISTER can be either human-friendly register name (e.g. "CO2") or register number (30001)
|
- REGISTER can be either human-friendly register name (e.g. "CO2") or register number (30001)
|
||||||
- read may have list of REGISTER arguments (combining both register numbers and names)
|
- read may have list of REGISTER arguments (combining both register numbers and names)
|
||||||
- VALUE is 16-bit integer in decimal format
|
- VALUE is 16-bit integer in decimal format
|
||||||
@ -78,7 +78,7 @@ while arg_index < len(argv):
|
|||||||
# sanity check
|
# sanity check
|
||||||
if not action:
|
if not action:
|
||||||
action = 'all'
|
action = 'all'
|
||||||
if action != 'read' and action != 'write' and action != 'all':
|
if action != 'read' and action != 'write' and action != 'all' and action != 'reset':
|
||||||
print(f'Unknown action {action}')
|
print(f'Unknown action {action}')
|
||||||
exit(-4)
|
exit(-4)
|
||||||
if action == 'write' and value == None:
|
if action == 'write' and value == None:
|
||||||
@ -140,4 +140,11 @@ elif action == 'write':
|
|||||||
except ValueError:
|
except ValueError:
|
||||||
print(f'Register number {reg_number} cannot be written')
|
print(f'Register number {reg_number} cannot be written')
|
||||||
exit(-9)
|
exit(-9)
|
||||||
|
elif action == 'reset':
|
||||||
|
if not s.reset():
|
||||||
|
# reset should throw NoResponse; if it doesn't, reset failed
|
||||||
|
print('Device reset failed!')
|
||||||
|
else:
|
||||||
|
print('---- Device reset ----')
|
||||||
|
|
||||||
exit(0)
|
exit(0)
|
||||||
|
@ -27,6 +27,8 @@ class Sensor():
|
|||||||
'SCD4x_temperature_offset': 40006, \
|
'SCD4x_temperature_offset': 40006, \
|
||||||
'MODBUS_address': 40007, \
|
'MODBUS_address': 40007, \
|
||||||
'baudrate': 40008 }
|
'baudrate': 40008 }
|
||||||
|
reset_register = 40100
|
||||||
|
reset_magic_number = 0xABCD
|
||||||
# readout and error counters
|
# readout and error counters
|
||||||
readout_total = 0
|
readout_total = 0
|
||||||
readout_error_invalid_response = 0 # checksum error: bus transmission corrupted?
|
readout_error_invalid_response = 0 # checksum error: bus transmission corrupted?
|
||||||
@ -49,6 +51,12 @@ class Sensor():
|
|||||||
def close(self):
|
def close(self):
|
||||||
self.serial.serial.close()
|
self.serial.serial.close()
|
||||||
self.serial = None
|
self.serial = None
|
||||||
|
def reset(self):
|
||||||
|
try:
|
||||||
|
self.write_register(self.reset_register, self.reset_magic_number)
|
||||||
|
return False # got answer => failed to reset
|
||||||
|
except minimalmodbus.NoResponseError:
|
||||||
|
return True # no answer => reset successful
|
||||||
# High level read functions
|
# High level read functions
|
||||||
@property
|
@property
|
||||||
def CO2(self):
|
def CO2(self):
|
||||||
|
Loading…
Reference in New Issue