Added exception handling for MODBUS checksum error
This commit is contained in:
parent
c8f12ffb4a
commit
555861e27c
@ -40,7 +40,7 @@ while True:
|
||||
T_SCD4x_signed = instrument.read_register(T_SCD4x_signed_addr, 1, functioncode=4, signed=True)
|
||||
with open(f'measurement_device_{slave_address}.csv', 'a+') as f:
|
||||
f.write(f'{time():.1f} {CO2} {T_SHT4x} {RH_SHT4x} {T_SCD4x} {RH_SCD4x} {T_SHT4x_signed} {T_SCD4x_signed}\n')
|
||||
except minimalmodbus.NoResponseError as e:
|
||||
except (minimalmodbus.NoResponseError, minimalmodbus.InvalidResponseError) as e:
|
||||
readout_error_count += 1
|
||||
with open('measure.log', 'a+') as logfile:
|
||||
logfile.write(f'Read error for device {slave_address} at {time()} ({str(e)}) ({readout_error_count}/{readout_count} readouts failed)\n')
|
||||
|
Loading…
Reference in New Issue
Block a user